| Type |
File Name |
Date Posted |
Size |
Description |
| GFK2123V.pdf | 04/09/10 | 188K | IC693CPU374-GV, CPU fw version 12.22/Enet fw version 4.52 |
| GFK2123U.pdf | 02/02/10 | 152K | IC693CPU374-GU, CPU fw version 12.21/Enet fw version 4.52 |
| GFK2123T.pdf | 06/12/09 | 151K | IC693CPU374-GT, CPU fw version 12.17/Enet fw version 4.52 |
| GFK2123S.pdf | 01/08/08 | 148K | IC693CPU374-GS, CPU fw version 12.16/Enet fw version 4.51 |
| GFK2123R.pdf | 08/31/07 | 152K | IC693CPU374-GR, CPU fw version 12.10 |
| GFK2123Q.pdf | 09/29/06 | 313K | IC693CPU374-GP, CPU fw version 12.04 Note: Versions -Dx and earlier cannot be upgradedto this hardware or firmware release. CPU374 hardware that is not compatible with CPU374-EK and later can be upgraded via the Trade Up program. Contact your local GE Fanuc representative or distributor for details on the Trade Up Program. |
| GFK2123P.pdf | 12/14/05 | 242K | IC693CPU374-FN, CPU fw version 12.03 |
| GFK2123N.pdf | 11/03/05 | 243K | IC693CPU374-FM, CPU fw version 12.02 |
| GFK2427A.pdf | 10/10/05 | 219K | IC693CPU374 firmware upgrade kit 11.23 |
| GFK2123M.pdf | 09/07/05 | 248K | IC693CPU374-EL, CPU fw version 12.01 |
| GFK2123L.pdf | 08/11/05 | 242K | IC693CPU374-EK, CPU fw version 12.00 |
| GFK2123H.pdf | 01/07/05 | 198K | IC693CPU374-BH, CPU fw version 11.21 |
| GFK2123G.pdf | 01/07/05 | 191K | IC693CPU374-BG, CPU fw version 11.10 |
| GFK2123E.pdf | 01/07/05 | 194K | IC693CPU374-BF, CPU fw version 11.04 |
| GFK2123D.pdf | 01/07/05 | 201K | IC693CPU374-BE, CPU fw version 11.03 |
| GFK2123C.pdf | 01/07/05 | 193K | IC693CPU374-BD, CPU fw version 11.02 |
| GFK2123B.pdf | 01/07/05 | 189K | IC693CPU374-AC, CPU fw version 11.01 |
| gfk2123.pdf | 01/07/05 | 432K | IC693CPU374-AB, CPU fw version 11.00 |
Publication Number: GFK-2123
Product history and release information for IC693CPU374
Description
| Rel. |
Ver. |
Date |
IPI |
Upgrade Kit |
New Features |
Problems Resolved |
| GV |
12.22/4.52 |
Mar-10 |
GFK-2123V |
82A1067-MS10-000-A5
|
NA |
PID execution issues |
| GU |
12.21/4.52 |
Sep-09 |
GFK-2123U |
82A1067-MS10-000-A4
|
Adds a customer-specific diagnostic feature. Does not affec product functionality or compatibility. |
NA |
| GT |
12.17/
4.52 |
May-09 |
GFK-2123T |
82A1067-MS10-000-A3
|
Additional Station Manager Capabilities |
See GFK-2123T |
| GS |
12.16 |
Jan-08 |
GFK-2123S |
82A1067-MS10-000-A2
|
N/A
|
EGD Consumer exchange status is now properly updated when current status is 7 (data and refresh error)
EGD Consumer exchange status is now properly updated when current status is 3 (data and refresh error)
|
| GR |
12.10 |
Aug-07 |
GFK-2123R |
82A1067-MS10-000-A1 |
Modbus Client TCP
Access to %W memory in remote PLCs that support the %W memory type via EGD Commands
Supernetting (Classless IP)
|
See GFK-2123R
|
| GP |
12.04 |
Apr-06 |
GFK-2123Q |
N/A |
N/A |
CPU374 no longer powers upwith OK and EOK LEDs off
|
| FN |
12.03 |
Dec-05 |
GFK-2123P |
44A751647-G04
Note: Versions -Dx and earlier cannot be upgradedto this hardware or firmware release. CPU374 hardware
that is not compatible with CPU374-EK and later can be upgraded via the Trade Up program. Contact your local GE Fanuc representative or distributor for details on the Trade Up Program.
|
N/A
|
Corrected "watchdog timeout" when unit is powered off several days without a battery.
|
| FM |
12.02 |
Nov-05 |
GFK-2123N |
44A751647-G03
Note: see upgrade note above
|
Improved support for some host communications toolkit versions
|
Corrected "reset of daughterboard" faults.
|
| EL |
12.01 |
Sep-05 |
GFK-2123M |
44A751647-G02
Note: see upgrade note above.
|
N/A
|
Corrected Run Mode store issue.
|
| EK |
12.00 |
Jun-05 |
GFK-2123L |
NA
Note: see upgrade note above.
|
SRTP Client Channels
EGD Class 2 Device Support
Web Server Support
|
Implementation of filtering for multicast Ethernet messages
|
| Dx and earlier |
11.23 |
Sept-05 |
GFK-2427A |
44A751579-G08 |
Filtering added for PID derivative term
|
Corrected Run Mode store issue.
|
| CJ |
11.22 |
Jan-05 |
GFK-2123K |
44A751579-G07 |
|
Loss/add of module faults with IC693ALG222/223 modules in CPU374 PLC
|
| BH |
11.21 |
Jun-04 |
GFK-2123H |
44A751579-G06 |
|
Serial Line Noise During SNP-X Communications May Stop CPU
SNP and SNP-X Ignore Parity Errors
|
| BG |
11.10 |
Feb-04 |
GFK-2123G |
44A751579-G05 |
|
Configurable Reference Tables Filled with Random Values after Size Change
Displayed Value of Free Memory Is Incorrect
CPU Error if Larger Reference Memory Configuration Stored after Maximum Size Program
EGD exchanges duplicated when powering on from flash
Ethernet interface may display fatal blink codes
Ethernet communications may fail after using Setip utility to assign IP address
|
| BF |
11.04 |
Aug-03 |
GFK-2123E |
44A751579-G04 |
|
Configurable Reference Tables Filled with Random Values after Size Change
|
| BE |
11.03 |
Jun-03
|
GFK-2123D |
44A751579-G03 |
|
Data From PBM200 Shifted When PBM In Expansion Rack and Main Rack Is Power Cycled
PLC Software Fault May Occur With Many SCADA/HMI Clients
|
| BD |
11.02 |
Dec-02 |
GFK-2123C |
44A751579-G02 |
|
Program Block Checksum Failure after Power-cycle & Stop to Run Transition with C
Clears All Memory after Run to Stop Transition with Multiple Power Cycles
|
| AC |
11.01 |
Dec-02 |
GFK-2123B |
44A751579-G01 |
|
Does Not Power Up or Powers Up with Corrupted Memory and/or Checksum Failure Faults
|
| AB |
11.00 |
May-02 |
GFK-2123 |
N/A |
Higher Performance CPU
EZ Program Store Device
SVCREQ #24
Embedded Network Switch
Two 10Base-T / 100Base-TX Auto-negotiating Full-Duplex Ethernet Ports
Ethernet Ports Auto Sense Straight or Crossover Connection
|
|
| Product | Version | Module |
| Series 90-30 |
All |
All |