| Product | Version | Module | | HMI/SCADA - iFIX |
All |
All |
Code : S_7
Hardware Manufacturer : Siemens Energy & Automation Inc.
General
| Platform |
Latest Version |
Type |
| Windows 2000 |
6.12 |
RES |
| Windows NT |
6.12 |
RES |
Supported
Devices
| Device |
Manufacturer |
Comment |
| S7-300 or S7-400 series CPU |
Siemens Energy & Automation Inc. |
- |
| S7-300 system |
Siemens Energy & Automation Inc. |
- |
| S7-400 system |
Siemens Energy & Automation Inc. |
- |
Additional
Requirements
| Software |
Manufacturer |
Vendor |
Part No. |
Comment |
| SIMATIC NCM S7 Diagnostics |
Siemens Energy & Automation Inc. |
Siemens Energy & Automation Inc. |
- |
Installed as option in Step7 package. |
| Simatic Net Industrial Communications |
Siemens Energy & Automation Inc. |
Siemens Energy & Automation Inc. |
|
|
| Step 7 V4.0 or higher |
Siemens Energy & Automation Inc. |
Siemens Energy & Automation Inc. |
- |
- |
Protocol
| Type |
Supported |
Baud Rates |
Data Bits |
Stop Bits |
Parity |
Error Checking |
Hand Shaking |
Comment |
| Communication Network |
Industrial Ethernet, standard Ethernet, or PROFIBUS (using S7 protocol only) |
- |
- |
- |
- |
- |
- |
- |
Supported
Data Types
| Data Type |
Comment |
| ASCII |
Text; use a Text block in the process database to read and write data |
| Byte |
8-bit unsigned |
| Counter |
Counter |
| Dint |
32-bit signed integer |
| Dword |
32-bit unsigned integer |
| Int |
16-bit signed integer |
| Real |
32-bit floating point |
| String |
Complex string defined in the PLC. (When you create a String the first two bytes are allocated for internal use.) |
| Timer |
Timer |
| Word |
16-bit unsigned integer |
Supported
Memory Types
| Device |
Memory Type |
Comment |
| none |
Commands
| Device |
Command |
Description |
Uses |
| All |
S7_Read (GET) |
Read several variables by a remote address |
- |
| All |
S7_Write (PUT) |
Send variable to a remote device by a remote address |
- |
Signal
Conditionings
| Signal Type |
Description |
Comment |
Typical Gain |
Convergance Range |
| 12AL |
12 Bit Binary Scaled to EGUs - Alarming on out of range |
Ignores most significant 4 bits (nibble). |
- |
- |
| 12BN |
12 Bit Binary Scaled to EGUs- No Alarming on out of range |
Ignores most significant 4 bits (nibble). |
- |
- |
| 15AL |
15 Bit Binary Scaled to EGUs - Alarming on out of range |
Ignores most significant bit. |
- |
- |
| 15BN |
15 Bit Binary Scaled to EGUs - No Alarming on out of range |
Ignores most significant bit. |
- |
- |
| 3BCD |
3 Digit Binary Coded Decimal |
Scaled to EGUs, Alarming on out of range.
Ignores most significant 4 bits (nibble). |
- |
- |
| 4BCD |
4 Digit Binary Coded Decimal |
Scaled to EGUs. Alarming on out of range. |
- |
- |
| 8AL |
8 Bit Binary Scaled to EGUs - Alarming on out of range |
Ignores most significant byte. |
- |
- |
| 8BN |
8 Bit Binary Scaled to EGUs - No alarming on out of range |
Ignores most significant byte. |
- |
- |
| LIN |
Value scaled to EGUs |
No alarming on out of range. Signed and Unsigned data types. |
- |
- |
| NONE |
Returns raw value |
No alarming on out of range. |
- |
- |
| S5TI |
No scaling. Converts the Siemens S5TIME format to seconds. |
- |
- |
- |
Miscellaneous
Info
| Relevant Notes |
| A CP 1613 PC board under Softnet is not supported. |
History
| Revision History |
Reason for 6.10 Release 9/25/98:
Added functionality for Block Writes which allows you to enable/disable multiple writes to a poll record.
Added functionality for CHAR (STRING) datatype support. STRING is a complex string defined in the PLC.
Reason for 6.10a Release on 2/8/99:
Updated documentation.
Reason for 6.10b Release on 6/14/99:
Corrected problems with the data being displayed by a controller when another controller is disconnected.
Reason for 6.10c Release on 11/4/99:
Corrected problems with importing a CSV file when using a Digital exception type with a BYTE or WORD data type.
Reason for 6.10d Release on 3/22/00:
Revised error messages to provide more information so that troubleshooting the driver is easier.
Reason for 6.10e Release on 5/30/00:
Corrected a problem with the driver; it was sometimes losing communications to device(s) when retries occur.
Reason for 6.11 Release on 6/27/01:
Added support for the CP 1613 and CP 5613 boards. Also added Windows 2000 support for these boards only.
Reason for 6.12 Release on 8/31/01:
Added Switch command to toggle manually between the primary and backup device defined in your driver configuration.
Reason for 6.12c Release on 12/12/01:
Corrected a problem with DB numbers greater then 2047.
The driver now accepts numbers from 0 to 4095. Also fixed a reply timeout problem. Previously the reply timeout was always 1 second. Now, the driver uses the reply timeout configured for it.
Reason for 6.12d Release on 6/10/02:
Corrected a problem with the reply timeout. If the timeout was less than 5 seconds, the driver could not recover from a network break. Now 5 seconds is the minimum reply timeout.
10/15/02:
Effective October 15, 2002, Intellution announces the obsolescence of the S_7 I/O driver. No new orders will be taken after this date. Per Intellution's obsolescence policy, SIMs will be produced for a period of 6 months (until 4/15/03). During that time, the driver will be posted on the Driver SIM area for download. Only existing S_7 customers participating in iGlobalCare are eligible for SIMs.
New customers should contact their Intellution Sales representative to help find a suitable alternative to the S_7.
Reason for 6.12e Release on 01/02/03:
Changed the CP Name pull-down field in the configuration tool to allow user selection and editable user entry.
Reason for 6.12f Release on 03/10/2003:
Modified documentation to comply with GE standards. |
|
|