GE Intelligent Platforms > Support >  Drivers - General > DG167
REA Reliance Elec. Automate 15/20/30/40
Type File Name Date Posted Size Description

There are files attached to this record that may require you to login.

 


Description

ProductVersionModule
HMI/SCADA - iFIX All All

Code : REA
Vendor : GE Intelligent Platforms
Hardware Manufacturer : Reliance Elec.
Notes : Available for use with FIX32 and iFIX only.

General

Platform Latest Version Type
Windows 2000 6.0 COM
Windows 3.1 5.3 COM
Windows 95 6.0 COM
Windows NT 6.0 COM

Supported
Devices

Device Manufacturer Comment
15 Reliance Elec. -
15E Reliance Elec. -
20 Reliance Elec. -
20E Reliance Elec. -
30 Reliance Elec. -
30E Reliance Elec. -
40 Reliance Elec. -
40E Reliance Elec. -
40X Reliance Elec. -

Additional
Requirements

Software Manufacturer Vendor Part No. Comment
none

Protocol

Type Supported Baud Rates Data Bits Stop Bits Parity Error Checking Hand Shaking Comment
R-Net AutoMate Selectable to 19200 - - None, Even, Odd - None, RTS/CTS, DTR/DSR -

Supported
Data Types

Data Type Comment
ASCII 8-bit character
Float 32-bit floating point (IEEE)
Signed Signed 16-bit integer
Unsigned Unsigned 16-bit integer

Supported
Memory Types

Device Memory Type Comment
15, 15E, 20, 20E, 30, 30E, 40, 40E, 40X Register -
15, 15E, 20, 20E, 30, 30E, 40, 40X Bit -
30, 30E, 40, 40E, 40X User Defined -

Commands

Device Command Description Uses
002 Write Point - -
003 Read Registers - -
004 Write Registers - -
047 Set Gateway Parameters - -

Signal
Conditionings

Signal Type Description Comment Typical Gain Convergance Range
12AL 12 Bit Binary Scaled to EGUs - Alarming on out of range Ignores most significant 4 bits (nibble). - -
12BN 12 Bit Binary Scaled to EGUs- No Alarming on out of range Ignores most significant 4 bits (nibble). - -
15AL 15 Bit Binary Scaled to EGUs - Alarming on out of range Ignores most significant bit. - -
15BN 15 Bit Binary Scaled to EGUs - No Alarming on out of range Ignores most significant bit. - -
3BCD 3 Digit Binary Coded Decimal Scaled to EGUs. Alarming on out of range. Ignores most significant 4 bits (nibble). - -
4BCD 4 Digit Binary Coded Decimal Scaled to EGUs. Alarming on out of range. - -
LIN Value scaled to EGUs No alarming on out of range. Signed and Unsigned data types. - -
NONE Returns raw value No alarming on out of range. - -

Miscellaneous
Info

Relevant Notes
none

History

Revision History
Reason for 6.00 Release on 12/19/95:
* Driver released including all previous SIMs.

Reason for 6.00a Release on 4/4/01:
* Corrected a problem with the Reload command being grayed
out under iFIX 2.5.

Reason for 6.00b Release on 6/10/05:
* Driver has been rebranded to reflect GE Fanuc.


Details
ID: DG167
Category: I/O Drivers
Last Updated: 03/29/10
Date Created: 04/24/00
Status: Published
Attachments: Yes
Language: English


 


Rate this content record (1=lowest, 5=highest)
5
4
3
2
1
Comment