GE Intelligent Platforms > Support >  Drivers - General > DG147
OP2 Opto 22 OPTOMUX v6.xx
Type File Name Date Posted Size Description

There are files attached to this record that may require you to login.

 


Description

ProductVersionModule
HMI/SCADA - iFIX All All

Code : OP2
Vendor : GE Intelligent Platforms
Hardware Manufacturer : Opto 22
Notes : Available for use with FIX32 and iFIX only.

General

Platform Version Type
Windows 95 / NT / 2000 / XP(SP2) / Server 2003 / Vista 6.40 COM

Supported
Devices

Device Manufacturer Comment
Optomux Brain Boards labelled "REV1" and higher. Opto 22 -

Additional
Requirements

Software Manufacturer Vendor Part No. Comment
none

Protocol

Type Supported Baud Rates Data Bits Stop Bits Parity Error Checking Hand Shaking Comment
Multi-Drop 2 pass protocol 110, 300, 600, 1200, 2400, 4800, 9600, 19200, 38400 7, 8 1, 2 None, Odd, Even - None, RTS/CTS, DTR/DSR -

Supported
Data Types

Data Type Comment
none

Supported
Memory Types

Device Memory Type Comment
none

Commands

Device Command Description Uses
All Clear Duration Counters - -
All Configure Positions - -
All Identify OPTOMUX Type - -
All Power Up Clear - -
All Read Analog Inputs - -
All Read Analog Outputs - -
All Read and Clear Counters - -
All Read and Clear Duration Counters - -
All Read and Clear Lowest Values - -
All Read and Clear Peak Values - -
All Read Lowest Values - -
All Read On/Off Status - -
All Read Peak Values - -
All Read Pulse Complete Bits - -
All Read Temperature Inputs - -
All Set Analog Watchdog Delay - -
All Set Digital Watchdog Delay - -
All Set Protocol - -
All Set Temperature Probe Type - -
All Set Time Delay - -
All Set Timer Resolution - -
All Start Counters - -
All Trigger On Positive Pulse - -
All Update Analog Outputs - -
All Write Outputs - -

Signal
Conditionings

Signal Type Description Comment Typical Gain Convergance Range
12AL 12 Bit Binary Scaled to EGUs - Alarming on out of range Ignores most significant 4 bits (nibble). - 0 - 4095
AD10 -60.0 to 812.0 degc (AD10) OR -76.0 to 1493.6 degf (RTD) 100 Ohm RTD input. - -60.0 to 812.0 degc OR -76.0 to 1493.6 degf
AD14 -55.0 to 100.0 degc OR -67.0 to 212.0 degf 10 Ohm RTD input. - -55.0 to 100.0 degc OR -67.0 to 212.0 degf
AD17 -50.0 to 1768.0 degc (AD17) OR -58.0 to 3214.4 degf (R or S) Type R or S Thermocouple. - -50.0 to 1768.0 degc OR -58.0 to 3214.4 degf
AD18 -200.0 to 400.0 degc (AD18) OR -328.0 to 752.0 degf (T) Type T Thermocouple. - -200.0 to 400.0 degc OR -328.0 to 752.0 degf
AD19 -100.0 to 900.0 degc (AD19) OR -148.0 to 1652.0 degf (E) Type E Thermocouple. - -100.0 to 900.0 degc OR -148.0 to 1652.0 degf
AD4 40.0 to 100.0 degc OR 40.0 to 212.0 degf IC Temperature Sensor. - 40.0 to 100.0 degc OR 40.0 to 212.0 degf
AD5 20.0 to 1200.0 degc (AD5) OR 4.0 to 2192.0 degf (J) Type J Thermocouple. - 20.0 to 1200.0 degc OR 4.0 to 21292.0 degf
AD8 125.0 to 1250.0 degc (AD8) OR 193.0 to 2282.0 degf (K) Type K Thermocouple. - 125.0 to 1250.0 degc OR 193.0 to 2282.0 degf
ALL Standard Fix Sig Conditioning Options Output Signal Conditioning; Read and Clear All Peaks and Valleys. - -
DURA 0 to 32767 for 1/100 secs or 0 to 327.67 for secs (above values) Pulse Duration. - -
LIN Value scaled to EGUs No alarming on out of range. Signed and Unsigned data types. - -
LSQR 1-5V. Square Root Scaled from low to high EGU Live Zero Square Root. - Any
LVZ 1-5V. Linear Scaled from low to high EGU Live Zero. - Any (e.g., 20.0 to 100.0 pct)
ONE Read and Clear peak and valley Output Signal Conditioning; Clear Peak and Lowest. - -
PEAK Read peak value (Linear) - - -
PRPH High Res 0.00 to 100.00 Output Signal Conditioning; High Resolution Square Wave. - -
PRPL Low Res 0.00 to 100.00 Output Signal Conditioning; Low Resolution Square Wave. - -
SQR Square Root Scaled low to high EGU - - Any
TOTL 0 to 32767 to get counts Totalizer. - -
VLY Read lowest value (Linear) - - -

Miscellaneous
Info

Relevant Notes
General Limitations:

Optomux Brain Boards labelled "REV1" and higher.

History

Revision History

Reason for 6.01c release on 6/6/97:
* Corrected problem with ADxx family of signal conditionings not clamping
the value when an out of range value was read. Now both HI and LO out
of range values are clamped to the HI EGU and an OVER or UNDER alarm is
returned.

Reason for 6.01d release on 4/21/99:
* Corrected problem of writes not going through on startup when using
the High Resolution Square Wave Module type and signal conditioning.
* Added AD08 and K08 signal conditioning.

Reason for 6.01e release on 6/10/05:
* Driver has been rebranded to reflect GE Fanuc.

Reason for 6.02 release on 08/10/2007:
* Validated operation under Windows XP/SP2.

Reason for 6.40 Service Pack release on 10/23/2007:
* OP2 now validated for use with Microsoft Vista OS.



Details
ID: DG147
Category: I/O Drivers
Last Updated: 03/29/10
Date Created: 04/24/00
Status: Published
Attachments: Yes