GE Intelligent Platforms > Support >  Drivers - General > DG145
OMF Omron Fins
Type File Name Date Posted Size Description

There are files attached to this record that may require you to login.

 


Description

ProductVersionModule
HMI/SCADA - iFIX All All

Code : OMF
Vendor : GE Intelligent Platforms
Hardware Manufacturer : Omron
Notes : Available for use with FIX32 and iFIX only.

General

Platform Latest Version Type
Windows NT, 2000, XP 6.23 NET

Supported
Devices

Device Manufacturer Comment
C-series PLC's Omron -
CV-series PLC's Omron -

Additional
Requirements

Software Manufacturer Vendor Part No. Comment
FinsGateway Version 2003 Omron Omron - Install one of the following four versions: Controller Link (CLK_Unit0), Serial Interface (SERIAL_Unit), Ethernet (ETN_Unit), or Sysmac Link (SysmacLink).

Protocol

Type Supported Baud Rates Data Bits Stop Bits Parity Error Checking Hand Shaking Comment
Communication Network FinsGateway API's - - - - - - -

Supported
Data Types

Data Type Comment
ASCII -
Digital -
Float -
Long (Signed) -
Long (Unsigned) -
Signed -
Structure -
Union Supports mixed data types of Slin, Slng, Flt, and Long as hardware options field in database block.
Unsigned -

Supported
Memory Types

Device Memory Type Comment
C Series PLCs AR -
C Series PLCs CIO -
C Series PLCs CNT -
C Series PLCs CNTPV -
C Series PLCs DM -
C Series PLCs HR -
C Series PLCs LR -
C Series PLCs TIM -
C Series PLCs TIMPV -
CV Series PLCs A -
CV Series PLCs ACFLS -
CV Series PLCs CIO -
CV Series PLCs CIOFRS -
CV Series PLCs CNTFRS -
CV Series PLCs CNTPV -
CV Series PLCs DM -
CV Series PLCs DMBANK0 to DMBANK7 -
CV Series PLCs DR -
CV Series PLCs EXPDM -
CV Series PLCs G -
CV Series PLCs GFRS -
CV Series PLCs INT -
CV Series PLCs IR -
CV Series PLCs ST -
CV Series PLCs STFLS -
CV Series PLCs STPV -
CV Series PLCs TIMFRS -
CV Series PLCs TIMPV -
CV Series PLCs TNFRS -
CV Series PLCs TR -
ETN ELOG -
SLK and CLK CNTLS -
SLK and CLK DLS -
SLK and CLK ELOG -
SLK and CLK NTS -
SNT CNTLS -
SNT DLS -
SNT ELOG -
SNT NAME -

Commands

Device Command Description Uses
C Series 0101 Memory area read -
C Series 0102 Memory area write -
C Series 0401 Run -
C Series 0402 Stop -
C Series 0601 Controller status read -
C Series 0701 Clock read -
C Series 0702 Clock write -
C Series 2101 Error clear -
CV Series 0101 Memory area read -
CV Series 0102 Memory area write -
CV Series 0104 Multiple memory area read -
CV Series 0401 Run Used in CMD parameter of CNTLS
CV Series 0402 Stop -
CV Series 0601 Controller status read -
CV Series 0620 Cycle time read -
CV Series 0701 Clock read -
CV Series 0702 Clock write -
CV Series 0920 Message read/write -
CV Series 2101 Error Clear -
CV Series 2102 Error Log Read -
CV Series 2103 Error Log Clear -
ETN 2102 Error log read -
ETN 2103 Error log clear -
SLK and CLK 0601 Controller status read -
SLK and CLK 0602 Network status read -
SLK and CLK 0603 Data link status read -
SLK and CLK 2102 Error log read -
SLK and CLK 2103 Error log clear -
SNT 0601 Controller status read -
SNT 0603 Data link status read -
SNT 2102 Error log read -
SNT 2103 Error log clear -
SNT 2601 Name set -
SNT 2603 Name read -

Signal
Conditionings

Signal Type Description Comment Typical Gain Convergance Range
12AL 12 Bit Binary Scaled to EGUs - Alarming on out of range Ignores most significant 4 bits (nibble). - -
12BN 12 Bit Binary Scaled to EGUs- No Alarming on out of range Ignores most significant 4 bits (nibble). - -
15AL 15 Bit Binary Scaled to EGUs - Alarming on out of range Ignores most significant bit. - -
15BN 15 Bit Binary Scaled to EGUs - No Alarming on out of range Ignores most significant bit. - -
3BCD 3 Digit Binary Coded Decimal Scaled to EGUs. Alarming on out of range. Ignores most significant 4 bits (nibble). - -
4BCD 4 Digit Binary Coded Decimal Scaled to EGUs. Alarming on out of range. - -
8AL 8 Bit Binary Scaled to EGUs - Alarming on out of range Ignores most significant byte. - -
8BN 8 Bit Binary Scaled to EGUs - No alarming on out of range Ignores most significant byte. - -
FLT Interpret 2 words in Word pollrec as float Union data type. Reads 4 bytes and converts it to an IEEE floating point value. - -
LIN Value scaled to EGUs No alarming on out of range. Signed and Unsigned data types. - -
LONG Interpret 2 words in Word pollrec as long Union data type. Reads 4 bytes and converts it to a 32-bit long value. - -
NONE Returns raw value No alarming on out of range. - -
SLIN Union data type. Scaled to EGU range in the block. No alarming on out of range. - - -
SLNG Reads 4 bytes and converts it to 32-bit signed long value. Union data type. - -

Miscellaneous
Info

Relevant Notes
4/4/01: NOT W2K COMPATIBLE DUE TO 3RD PARTY CONSTRAINTS.

All command codes are BCD values.



05/19/2006: Now Windows/2000 and Windows/XP compatible - requires use of Omron FinsGateway Version 2003.

History

Revision History
Reason for 4/3/98 Release:
* Added support for Controller Link network and added support for UNION datatype.

Reason for 10/16/98 Release:
* Corrected problem with Word order of LongInt and also Float data being incorrect. LSB must be first in device memory.

Reason for 1/22/99 Release:
* Corrected problem of TIM memory type not being addressable as a digital data point.

Reason for 3/9/99 Release:
* Corrected problem of TIM flag completion data not being read correctly.

Reason for 6.22 Release on 5/7/99:
* Added support for Omron FINS v2.1 software.

Reason for 6.22a Release on 11/11/00:
* Corrected a problem with high CPU usage when some of the devices were off-line.

Reason for 6.22b Release on 08/17/2005:
* Updated to reflect GE Fanuc branding..

Reason for 6.23 release on 05/19/2006:
* Driver rebuilt and tested running under Windows/2000 and Windows/XP. Requires Omron FinsGateway Version 2003.

Reason for 6.23a release on 04/21/2008:
* Driver enhanced to allow configurable limits for maximum number of outstanding messages. It was discovered through testing that some network interfaces (e.g. CLK32 optical interface) may have problems handling more than ~8 outstanding messages. Configuration details can be found in the OMFRel.txt release notes file. Please note: Under normal circumstances, no changes to the default limits are required.
 


Details
ID: DG145
Category: I/O Drivers
Last Updated: 03/29/10
Date Created: 04/24/00
Status: Published
Attachments: Yes