| Type |
File Name |
Date Posted |
Size |
Description |
There are files attached to this record that may require you to login. |
| Product | Version | Module | | HMI/SCADA - iFIX |
All |
All |
Code : MT1
Hardware Manufacturer : Mitsubishi
Notes : Available for use with FIX32 and iFIX only.
General
| Platform |
Latest Version |
Type |
| Windows 2000 |
6.01 |
COM |
| Windows 3.1 |
5.33 |
COM |
| Windows 95 |
6.01 |
COM |
| Windows NT |
6.01 |
COM |
Supported
Devices
| Device |
Manufacturer |
Comment |
| Analog Multiplexers |
MT1 |
- |
| Counter / Multiplexers |
MT1 |
- |
| Counters |
MT1 |
- |
Additional
Requirements
| Software |
Manufacturer |
Vendor |
Part No. |
Comment |
| none |
Protocol
| Type |
Supported |
Baud Rates |
Data Bits |
Stop Bits |
Parity |
Error Checking |
Hand Shaking |
Comment |
| Direct Link |
- |
110, 300, 600, 1200, 2400, 4800, 9600, 19200, 38400 |
7, 8 |
1, 2 |
None, Odd, Even |
- |
None, RTS/CTS, DTR/DSR |
- |
Supported
Memory Types
| Device |
Memory Type |
Comment |
| none |
Commands
| Device |
Command |
Description |
Uses |
| All Devices |
128 to 191 |
- |
Counter Select |
| All Devices |
192 to 255 |
- |
Device Select |
| All Devices |
A |
- |
Send Record |
| All Devices |
c - Lower case |
- |
Start Counting |
| All Devices |
C - Upper case |
- |
Clear Buffer |
| All Devices |
e |
- |
Stop Counting |
| All Devices |
g |
- |
Active Mode |
| All Devices |
h |
- |
Standby Mode |
| All Devices |
o |
- |
Digital Output |
Signal
Conditionings
| Signal Type |
Description |
Comment |
Typical Gain |
Convergance Range |
| 11AL |
Scaled to EGU range in the block. Range checking Alarming. |
Ignores the most significant 5 bits. |
- |
0 - 2048 |
| 12AL |
12 Bit Binary Scaled to EGUs - Alarming on out of range |
Ignores the most significant 4 bits (nibble). |
- |
0 - 4095 |
| 12BN |
12 Bit Binary Scaled to EGUs- No Alarming on out of range |
Ignores the most significant 4 bits (nibble). |
- |
0 - 4095 |
| LIN |
Value scaled to EGUs |
No alarming on out of range. Signed and Unsigned data types. |
- |
0 -4095 |
| NONE |
Returns raw value |
No alarming on out of range. |
- |
- |
Miscellaneous
Info
| Relevant Notes |
Hardware:
Maximum CHANNELS Supported: 8
PERFORMANCE:
Customers should be encouraged to use as many channels as
possible when they have a large number of Met One devices
to talk to. It is also strongly recommended to have a huge
delay and fewer number of retries when they have many
devices offline on the same channel.
CABLING:
Consult your Met One Users Manual for information.
UNSOLICITED MESSAGES:
Not Supported on Windows NT or Windows 95
NOTE:
The Analog Multiplexer returns a maximum value of 4095 and
hence LIN signal conditioning scales accordingly. |
History
| Revision History |
Reason for 6.01 release on 11/14/1996:
* Built to incorporate changes made in the Windows driver.
Reason for 6.01a release on 08/02/1999:
* Corrected the problem of a device failing on one channel affecting the polling of devices on other channels.
Reason for 6.01b release on 01/27/2006:
* When the device CTL (control bit) was cleared, the command to set the device to StandBy mode was being sent repeatedly, without a delay between messages. The customer's device required a delay of at least 1.5 seconds between command messages. The Channel Delay parameter is now used to configure this delay.
* Branding changed in driver and documentation to reflect GE Fanuc. |
|
|