| Type |
File Name |
Date Posted |
Size |
Description |
There are files attached to this record that may require you to login. |
| Product | Version | Module | | HMI/SCADA - iFIX |
All |
All |
Code : JYC
Hardware Manufacturer : Johnson-Yokogawa
Notes : Available for use with FIX32 and iFIX only.
General
| Platform |
Latest Version |
Type |
| Windows 2000 |
6.0 |
COM |
| Windows 3.1 |
4.2 |
COM |
| Windows 95 |
6.0 |
COM |
| Windows NT |
6.0 |
COM |
Supported
Devices
| Device |
Manufacturer |
Comment |
| YS150 Single Loop Multi-Function Controller (Series 1 and 2) |
Johnson-Yokogawa |
- |
| YS170 Single Loop Programmable Controller (Series 1 and 2) |
Johnson-Yokogawa |
- |
Additional
Requirements
| Software |
Manufacturer |
Vendor |
Part No. |
Comment |
| none |
Protocol
| Type |
Supported |
Baud Rates |
Data Bits |
Stop Bits |
Parity |
Error Checking |
Hand Shaking |
Comment |
| Multi-Drop |
Asynchronous, half-duplex, ASCII codes, Yokogawa TTY Procedure, Vertical Parity Error Detection. |
1200, 2400, 4800, and 9600 |
7, 8 |
1, 2 |
None, Odd, Even |
None, RTS/CTS, DTR/DSR, RTS |
- |
- |
Supported
Memory Types
| Device |
Memory Type |
Comment |
| Cascade Hardware Mode |
A1, A2, X1, G1, G1A, G2, G2A, G1D, S1, S2, T1, T2, CFG |
- |
| Program Hardware Mode (YS170 only) |
A1, A2, A3, A4, K1, P1, PGM, PP1, T, X1, G1, G1A, G2, G2A, G1D, S1, S2, T1, BS1, T2, BS2, CFG |
- |
| Selector Hardware Mode |
A1, A2, X1, G1, G1A, G2, G2A, G1D, S1, S2, T1, T2, CFG |
- |
| Single Hardware Mode |
A1, X1, G1, G1A, G1D, S1, T1, CFG |
- |
Commands
| Device |
Command |
Description |
Uses |
| All Devices |
DG |
Data Read Command: for reading data from YS100 Series controllers. |
- |
| All Devices |
DP |
Data Write Command: for setting YS100 Series controllers. |
- |
| All Devices |
WDT |
Supervisory Computer Watchdog Timer Setting Command in DDC and SPC modes: for initial setting and maintaining of the YS100 Series supervisory computer watchdog timer. |
- |
Signal
Conditionings
| Signal Type |
Description |
Comment |
Typical Gain |
Convergance Range |
| EGU |
Scales parameter value to SCLx, SCHx, and SCDPx of appropriate loop. |
Since the range low limit, range high limit, and depth are gathered within data group CFG, and if this group is not configured within a poll record for the device, no scaling will be performed. |
- |
- |
| NONE |
Returns raw value |
No alarming on out of range. |
- |
- |
History
| Revision History |
Reason for 6.00 Release on 4/8/96:
* Driver released including all previous SIMs.
Reason for 6.00a Release on 9/25/98:
* Corrected problem of driver transmitting even if NONE was
selected as the primary COM port.
Reason for 6.00b Release on 10/30/00:
* Corrected a problem with the driver rejecting certain I/O
addresses entered for second channel.
Reason for 6.00c Release on 10/03/03:
* Corrected problem with poll task hanging when there was noise on the serial connection.
Reason for 6.00d Release on 6/9/2005:
* Driver has been rebranded to reflect GE Fanuc. |
|
|