| GE Intelligent Platforms > Support > Drivers - General > DG52 |
| EIM Honeywell/EIM 620 |
Description
Code : EIM
Notes : Available for use with FIX32 and iFIX only.
Additional
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Software | Manufacturer | Vendor | Part No. | Comment |
| none | ||||
| Type | Supported | Baud Rates | Data Bits | Stop Bits | Parity | Error Checking | Hand Shaking | Comment |
| TCP/IP | - | - | - | - | - | - | - | - |
| Data Type | Comment |
| FLOAT | Memory Type: F |
| SIGNED | Memory Type: R |
| STRUCT | Memory Type: All ELPM Supported Structures |
| UNSIGNED | Memory Type: R, I, S |
| Device | Memory Type | Comment |
| All | - | Note: Structure types require ELPM Module on PLC |
| All | F | Floats |
| All | I | I/O Points |
| All | R | Registers |
| All | S | Status Registers |
| All (Requires ELPM Interface) |
AI | Analog Input |
| All (Requires ELPM Interface) |
AO | Analog Output |
| All (Requires ELPM Interface) |
Operator Tags | Read and Write Analog/Digital Value for Specified Operator Tag |
| All (Requires ELPM Interface) |
RDIG | Read Digital |
| All (Requires ELPM Interface) |
RTD | Resistance Temperature Detector |
| All (Requires ELPM Interface) |
WDIG | Write Digital |
| All (Requires ELPM Interface) |
WREG | Write Registers |
| All (Requires ELPM Interface) |
WRG8 | Write Analog Input to any of 8 Registers |
| All (Requires ELPM Interface) |
PID1 | PID Loop |
| All (Requires ELPM Interface) |
PID2 | PID2 Loop for Cascade |
| All (Requires ELPM Interface) |
PID3 | PID 3 Loop for Cascade with Interlocks |
| All (Requires ELPM Interface) |
RFP8 | Read Register and Convert to Scaled EGUs |
| All (Requires ELPM Interface) |
RREG | Read Registers |
| All (Requires ELPM Interface) |
RRG8 | Read Register and Convert to Scaled EGUs |
| All (Requires ELPM Interface) |
RTD8 | Multichannel Resistance Temperature Detector |
| All (Requires ELPM Interface) |
SPP | Set Point Programmer |
| All (Requires ELPM Interface) |
TOT | Totalizer |
| All (Requires ELPM Interface) |
UAI | Universal Analog Input |
| All (Requires ELPM Interface) |
UAI6 | Read UAI and Convert to EGUs |
| All (Requires ELPM Interface) |
WFP8 | Write Register and Convert to Scaled EGUs |
| Device | Command | Description | Uses |
| All Devices | 02 | Contiguous Floating Point 32-bit Values (Used for Structure Read) | - |
| All Devices | 03 | Scattered Floating Point 32-bit Values (Used for structure Write) | - |
| All Devices | 20 | Contiguous I/O Status Points | - |
| All Devices | 22 | Contiguous Unsigned Registers and Floats | - |
| All Devices | 28 | Contiguous System Status (Undocumented) | - |
| Signal Type | Description | Comment | Typical Gain | Convergance Range |
| 12AL | 12 Bit Binary Scaled to EGUs - Alarming on out of range | Ignores most significant 4 bits (nibble). | - | 0 -4095 |
| 12BN | 12 Bit Binary Scaled to EGUs- No Alarming on out of range | Ignores most significant 4 bits (nibble). | - | 0 - 4095 |
| 15AL | 15 Bit Binary Scaled to EGUs - Alarming on out of range | Ignores most significant bit. | - | 0 - 32767 |
| 15BN | 15 Bit Binary Scaled to EGUs - No Alarming on out of range | Ignores most significant bit. | - | 0 - 32767 |
| 3BCD | 3 Digit Binary Coded Decimal | Scaled to EGUs. Alarming on out of range. Ignores most significant 4 bits (nibble). | - | 0 - 999 |
| 4BCD | 4 Digit Binary Coded Decimal | Scaled to EGUs. Alarming on out of range. | - | 0 - 9999 |
| LSQR | 1-5V. Square Root Scaled from low to high EGU | - | - | - |
| NONE | Returns raw value | No alarming on out of range. | - | - |
| SGNLIN | Signed Linear | No alarming on out of range. | - | -32768 - 32767 |
| SQRT | Square Root | - | - | - |
| UNSGNLIN | Unsigned Linear | No alarming on out of range. | - | 0 - 65535 |
| Relevant Notes |
| NOTE: Not W2K Compatible due to 3rd party constraints. CABLING: The ELPM and EIM Module support either one of these connections: Coaxial 10 Base2 (Thinnet) Cable Connector OR 10 Base5 Attachment Unit Interface (AUI) 15 pin connector NOTE: Default factory setting uses Coaxial connection. CONFIGURATION LIMITATIONS: Maximum CHANNELS Supported: 8 Maximum DEVICES Supported: 31 Performance: The driver performance was tested with the following testbed: PC: Pentium with 133 Mhz, with 3COM Etherlink III Adaptor HardDisk: 840MB RAM: 32MB FILE TYPE POLL RECORD LENGTH POLLTIME PERIOD NO.OF MSG/SEC Structures 1 Maximum 0 16 Structures 1 Maximum 0 1 40 Basic Types 1 Maximum 0 5 15 Basic Types 1 Maximum 0 1 22 Notes: 1) The average number of messages per second was calculated after at least 1000 messages had been sent. 2) For structures, even though driver allows user to configure a length greater than 1, the protocol does not allow all the structures to be read in with one command. The driver has to send one command each to read I/O and configuration parameters. As an example, if a PID1 type poll record is configured with maximum length (32) and configuration parameters are to be read every poll time, the driver has to send 64 message (32 * 2) to update the entire poll record. 3) We ran a test with one device and one structure type poll record per channel (4 channels). All poll records had a poll time of 0 and period was 1. The average number of messages per second was 76 (19 messages per channel per second). ADDRESS RANGE: MEM TYPE HARDWARE ADDR. RANGE MAX. LENGTH DID EXAMPLE I ALL 0 - 4095 224 I:102 R 620-12 0 -255,4096-4351 122 R:4150 620-1633 0 - 1023,4096-8191 122 R:7100 620-36 0 - 2039,4096-8191 122 R:2200 S ALL 0 - 4095 224 S:2402 F 620-12 0 - 255,4096-4351 60 F:224 620-1633 0 - 1023,4096-8191 60 F:5816 620-36 0 - 2039, 4096 - 8191 60 F:5814 AI ALL 1 - 250 250 AI:234 AO ALL 1 - 250 250 AO:200 PID1 ALL 1 - 32 32 PID1:10 PID2 ALL 1 - 32 32 PID2:10 PID3 ALL 1 - 32 32 PID3:10 PID2 ALL 1 - 32 32 PID2:10 RREG ALL 1 - 250 250 RREG:50 RDIG ALL 1 - 250 250 RDIG:50 RTD ALL 1 - 250 250 RTD:20 RTD8 ALL 1 - 250 250 RTD8:20 SPP ALL 1 - 8 8 SPP:5 TOT ALL 1 - 32 32 TOT:30 UAI ALL 1 - 250 250 UAI:10 WDIG ALL 1 - 250 250 WDIG:10 WREG ALL 1 - 250 250 WREG:10 Notes: 1. With Ver 6.10, the maximum length for I-Type has been reduced to 224 (from 244 in Ver. 6.00). This is because if a length of 244 is used, it is found that the last 20 values are not correct. 2. The total maximum number of structures allowed on PLC is 250. |
| Revision History |
| Reason for 6.20a Release on 4/10/98: Added multiple messaging to the existing I/O Driver to improve performance on systems that have multiple PLCs. Reason for 6.20b Release on 9/15/98: Corrected problem with negative values not being read correctly. Reason for 6.20c Release on 1/12/99: Corrected problem of not being able to read/write ASCII data. Reason for 6.20d Release on 3/24/99: Updated driver electronic book and on-line help. Reason for 6.20e Release on 5/26/05: * Updated documentation for branding, and fixed documentation spelling of "ALMHYST" to "ALHYST" for the address parameter. |
(22 responses)
Note: If your firewall blocks ZIPS and EXEs, simply right-click and select SAVE TARGET AS and change the extension to something like "XIP". Once downloaded change the extension back to its original one.
All drivers produced by vendors other than GE ("3rd Party Drivers") are provided by GE "as is" and without warranty of any kind unless the vendor extends a pass-through warranty to the end user. Support for 3rd Party Drivers is provided by the driver's vendor.
Knowledge Base |
Technical Documentation |
Downloads |
Products |
Forums |
Contact Support |
Privacy Policy |
Terms of Conditions |
Contact Us |