GE Intelligent Platforms > Support >  Drivers - General > DG13
ADM Azonix 1050, 1060, 6000
Type File Name Date Posted Size Description

There are files attached to this record that may require you to login.

 


Description

ProductVersionModule
HMI/SCADA - iFIX All All

Code : ADM
Vendor : GE Intelligent Platforms
Hardware Manufacturer : Azonix
Notes : Available for use with FIX32 and iFIX only.

General

Platform Latest Version Type
Windows 2000 6.0 COM
Windows 95 6.0 COM
Windows NT 6.0 COM

Supported
Devices

Device Manufacturer Comment
Micro Mac 1050 Azonix -
Micro Mac 1060 Azonix -
Micro Mac 6000c Azonix -

Additional
Requirements

Software Manufacturer Vendor Part No. Comment
none

Protocol

Type Supported Baud Rates Data Bits Stop Bits Parity Error Checking Hand Shaking Comment
RS-232 1050--MCComm3,
1060 AND 6000--MACCS
300 TO 19200 8 1 NONE - - -

Supported
Data Types

Data Type Comment
1050: AI Analog Input
1050: AO Analog Output
1050: DG Digital I/O Ports - Can install up to 8 digital ports per unit.
1050: EV Event Counters
1050: EVR Event Counter Read/Reset
1050: PC Low Speed Pulse I/O Configuration
1050: PO Pulse Output
1060 & 6000: ASCII 8-bit character
1060 & 6000: Long Integer Unsigned 32-bit integer
1060 & 6000: Real 32-bit floating point (IEEE)
1060 & 6000: Signed Signed 16-bit integer
1060 & 6000: Unsigned Unsigned 16-bit integer

Supported
Memory Types

Device Memory Type Comment
none

Commands

Device Command Description Uses
1050 AICNFG Configures conversion integration period and expansion panels. -
1050 AIN Returns scaled values from analog input channels. -
1050 AOT Writes scaled values to analog output channels. -
1050 AOTR Returns scaled output values from analog output channels. -
1050 DICNFG Specifies filter time, low-speed pulse I/O channels, latch input changes, and the edge level. -
1050 DIN Returns 8-bit values from digital input channels. -
1050 DOT Writes 8-bit values to digital output channels. -
1050 DTYPE Configures the channels on digital ports. -
1050 EVLOAD Loads event counters with an initial value. -
1050 EVRDRS Returns the current value of the event counter then resets the counter. -
1050 EVREAD Returns the current value of event counters. -
1050 EVSTART Starts event counting. -
1050 EVSTOP Stops event counting. -
1050 INTYPE Configures and activates analog input channels -
1050 OUTYPE Configures analog output channels. -
1050 POSET Configures pulse output channels. -
1050 POSTART Starts pulse output. -
1050 POSTOP Stops pulse output. -
1060 READ AND WRITE Integer, Real, Long, ASCII -
6000c READ AND WRITE Integer, Real, Long, ASCII -

Signal
Conditionings

Signal Type Description Comment Typical Gain Convergance Range
12AL 12 Bit Binary Scaled to EGUs - Alarming on out of range Ignores most significant 4 bits (nibble). (1060 & 6000) - -
12BN 12 Bit Binary Scaled to EGUs- No Alarming on out of range Ignores most significant 4 bits (nibble). (1060 & 6000) - -
15AL 15 Bit Binary Scaled to EGUs - Alarming on out of range Ignores most significant bit. (1060 & 6000) - -
15BN 15 Bit Binary Scaled to EGUs - No Alarming on out of range Ignores most significant bit. (1060 & 6000) - -
3BCD 3 Digit Binary Coded Decimal Scaled to EGUs. Alarming on out of range. Ignores most significant 4 bits (nibble). (1060 & 6000) - -
4BCD 4 Digit Binary Coded Decimal Scaled to EGUs. Alarming on out of range. (1060 & 6000) - -
8AL 8 Bit Binary Scaled to EGUs - Alarming on out of range Ignores most significant byte. (1060 & 6000) - -
8BN 8 Bit Binary Scaled to EGUs - No alarming on out of range Ignores most significant byte. (1060 & 6000) - -
BN12 Scaled to EGU range. No alarming on out of range. (1060 & 6000) - -
BN15 Scaled to EGU range. No alarming on out of range. (1060 & 6000) - -
BY12 Scaled to EGU range. Over and under range supported. No alarming on out of range. (1060 & 6000) - -
BY15 Scaled to EGU range. Over and under range supported. No alarming on out of range. (1060 & 6000) - -
LIN Value scaled to EGUs No alarming on out of range. Signed and Unsigned data types. (1050, 1060, & 6000) - -
NONE Returns raw value No alarming on out of range. (1050, 1060, & 6000) - -

Miscellaneous
Info

Relevant Notes
none

History

Revision History
Reason for 1/9/97 Release:
* Driver released including all previous SIMs.

Reason for 6.00d Release on 7/20/98:
* Corrected problem with not being able to enter a poll
record end address greater than 59 when defining REAL data.

Reason for 6.00e Release on 1/7/99:
* Corrected problem with Database Builder/VIEW displaying
incorrect values for data contained in EVR poll record.

Reason for 6.00f Release on 10/7/99:
* Corrected .CSV import problem where MOD type was getting
set to end address.

Reason for 6.00g Release on 07/06/01:
* Corrected a problem with the alarms sent to the Alarm
History service.

Reason for 6.00h Release on 06/02/2005:
* Driver has been rebranded to reflect GE Fanuc.


Details
ID: DG13
Category: I/O Drivers
Last Updated: 03/29/10
Date Created: 04/24/00
Status: Published
Attachments: Yes
Language: English


 


Overall Rating: 3.33 (3 responses)
Rate this content record (1=lowest, 5=highest)
5
4
3
2
1
Comment


Note:  If your firewall blocks ZIPS and EXEs, simply right-click and select SAVE TARGET AS and change the extension to something like "XIP".  Once downloaded change the extension back to its original one.

All drivers produced by vendors other than GE ("3rd Party Drivers") are provided by GE "as is" and without warranty of any kind unless the vendor extends a pass-through warranty to the end user.  Support for 3rd Party Drivers is provided by the driver's vendor.