| Product | Version | Module | | HMI/SCADA - iFIX |
All |
All |
Code : ABD
Hardware Manufacturer : Allen-Bradley
Notes : Available for use with FIX32 and iFIX only.
General
| Platform |
Version |
Type |
| Windows 95 / NT / 2000 / XP(SP2) / Server 2003 / Vista |
6.40 |
COM |
Supported
Devices
| Device |
Manufacturer |
Comment |
| Mailbox |
Allen-Bradley |
- |
| MicroLogix PLCs |
Allen-Bradley |
- |
| PLC-2 |
Allen-Bradley |
- |
| PLC-3 |
Allen-Bradley |
- |
| PLC-5 |
Allen-Bradley |
- |
| PLC-5/250 |
Allen-Bradley |
- |
| SLC-5 |
Allen-Bradley |
- |
| SLC-5/04 |
Allen-Bradley |
- |
Additional
Requirements
| Software |
Manufacturer |
Vendor |
Part No. |
Comment |
| none |
Protocol
| Type |
Supported |
Baud Rates |
Data Bits |
Stop Bits |
Parity |
Error Checking |
Hand Shaking |
Comment |
| Communication Network |
Driver Communicates DF1 half Duplex to Interface Module which can Talk DH or DH+ (WinNT, Win95) |
Selectable from 110 to 38400 |
7, 8 |
1, 2 |
None, Even, Odd |
CRC, BCC
(BCC recommended) |
None, RTS Delay |
- |
Supported
Data Types
| Data Type |
Comment |
| Adapter |
PLC-5/250 Adapter Status structure |
| ASCII |
8-bit character |
| Control |
Control structure |
| Counter |
Counter structure |
| Float |
32-bit floating point (IEEE) |
| Long |
Unsigned 32-bit integer |
| MSG |
PLC Message structure |
| PID |
PID structure |
| Signed |
Signed 16-bit integer |
| String |
ASCII String storage area |
| Timer |
Timer structure |
| Unsigned |
Unsigned 16-bit integer |
Supported
Memory Types
| Device |
Memory Type |
Comment |
| PLC-2 |
N/A |
Starting Address Range: 10-37777 Octal excluding 78-109 |
| PLC-3 |
O, I, T, C, N, D, B, S, F |
Output, Input, Timer, Counter, Integer, BCD, Binary, Status, Float |
| PLC-5 |
O, I, T, PD, C, N, D, B. S. F. A, L, R, MSG, ST |
Output, Input, Timer, PID Control, Counter, Integer, BCD, Binary, Status, Float, ASCII, Long, Control, Message Control, String |
| PLC-5/250 |
IS, O, I, T, C, N, B, S, F, L, R, PD, MSG, BTD. AS. ST |
Internal Storage, Output, Input, Timer, Counter, Integer, Binary, Public Status, Float, Long, Control, PID Block, Message Control, Block Transfer Data, Adapter Status, String |
| SLC-5 |
T, C, N, B, S, R |
Timer, Counter, Integer, Binary, Status, Control |
| SLC-5/04 |
O, I, T, C, N, F, B, A, ST, S, R |
Output, Input, Timer, Counter, Integer, Float, Binary, ASCII, String, Status, Control |
Commands
| Device |
Command |
Description |
Uses |
| Mailbox |
PLC2 Unprotected Write/ Unprotected Read |
- |
- |
| PLC-2 |
Write Digital Blocks, Write Analog Blocks, Read Analog Blocks |
- |
- |
| PLC-3 |
Write Digital Blocks, Write Analog Blocks, Read Data Blocks |
- |
- |
| PLC-5 |
Write Digital Blocks, Write Analog Blocks, Read Data Blocks |
- |
- |
| PLC-5/250 |
Write Digital Blocks, Write Analog Blocks, Read Data Blocks |
- |
- |
| SLC-5 |
Read Digital Blocks, Read Analog Blocks, Write Digital Bits |
- |
- |
| SLC-5/04 |
Read Digital Blocks, Read Analog Blocks, Write Digital Bits |
- |
- |
Signal
Conditionings
| Signal Type |
Description |
Comment |
Typical Gain |
Convergance Range |
| 12AL |
12 Bit Binary Scaled to EGUs - Alarming on out of range |
Ignores most significant 4 bits (nibble). |
- |
- |
| 12BN |
12 Bit Binary Scaled to EGUs- No Alarming on out of range |
Ignores most significant 4 bits (nibble). |
- |
- |
| 15AL |
15 Bit Binary Scaled to EGUs - Alarming on out of range |
Ignores most significant bit. |
- |
- |
| 15BN |
15 Bit Binary Scaled to EGUs - No Alarming on out of range |
Ignores most significant bit. |
- |
- |
| 3BCD |
3 Digit Binary Coded Decimal |
Scaled to EGUs. Alarming on out of range. Ignores most significant 4 bits (nibble). |
- |
- |
| 4BCD |
4 Digit Binary Coded Decimal |
Scaled to EGUs. Alarming on out of range. |
- |
- |
| 8AL |
8 Bit Binary Scaled to EGUs - Alarming on out of range |
Ignores most significant byte. |
- |
- |
| 8BN |
8 Bit Binary Scaled to EGUs - No alarming on out of range |
Ignores most significant byte. |
- |
- |
| LIN |
Value scaled to EGUs |
No alarming on out of range. Signed and Unsigned data types. |
- |
- |
| NONE |
Returns raw value |
No alarming on out of range. |
- |
- |
History
| Revision History |
Reason for 1/9/97 Release:
* Driver released including all previous SIMs.
Reason for 1/13/97 Release:
* Driver released including all previous SIMs.
Reason for 6/22/98 Release:
* Corrected problem of driver always using COMM1.
Reason for 6.12 Release on 10/19/98:
* Added support for MicroLogix 1000 and MicroLogix 1000 Analog processors. Updated documentation.
Reason for 6.12a Release on 5/5/99:
* Added new I/O address field. Refer to documentation for further information.
Reason for 6.12b Release on 3/16/00:
* Changed the driver to re-send a poll-ENQ when a message with an invalid transaction id is received. We were re-sending the entire request causing the buffers in the process hardware to fill up.
Release for 6.12c Release on 7/3/02:
* Corrected a problem with disabling a single PLC using the #DISABLE I/O address.
Reason for 6.12d Release on 6/2/05:
* Driver has been rebranded to reflect GE Fanuc.
Reason for 6.13 Release on 9/16/2005:
* Driver is now supported on Windows XP and Windows Server 2003.
Reason for 6.40 Service Pack release on 10/23/2007:
* ABD now validated for use with Microsoft Vista OS. |
|
|