| Type |
File Name |
Date Posted |
Size |
Description |
There are files attached to this record that may require you to login. |
| Product | Version | Module | | HMI/SCADA - iFIX |
All |
All |
Code : TTS
Hardware Manufacturer : Toshiba International Corporation
Notes : Available for use with FIX32 and iFIX only.
General
| Platform |
Latest Version |
Type |
| Windows 2000 |
6.01 |
COM |
| Windows 95 |
6.01 |
COM |
| Windows NT |
6.01 |
COM |
Supported
Devices
| Device |
Manufacturer |
Comment |
| EX-100 Series |
Toshiba International Corporation |
- |
| Prosec T-Series |
Toshiba International Corporation |
- |
Additional
Requirements
| Software |
Manufacturer |
Vendor |
Part No. |
Comment |
| none |
Protocol
| Type |
Supported |
Baud Rates |
Data Bits |
Stop Bits |
Parity |
Error Checking |
Hand Shaking |
Comment |
| Communication Network |
Computer Link Functions
(Serial, RS-485, Multi-drop protocol) |
110 to 38400 |
7, 8 |
1, 2 |
None, Odd, Even |
- |
None, RTS/CTS,
DTR/DSR |
Up to 100 EX-100 controllers or up to 32 T-Series PLCs can be linked. |
Supported
Data Types
| Data Type |
Comment |
| ASCII |
8 bit character data |
| DIGITAL |
1 bit data |
| FLOAT |
32 bit IEEE floating point |
| LONG/SLONG |
32 bit unsigned and signed data |
| SIGNED INT |
16 bit signed integer |
| STRUCTURE |
ASCII data |
| UNSIGNED INT |
16 bit unsigned integer |
Supported
Memory Types
| Device |
Memory Type |
Comment |
| All |
C |
Counter register |
| All |
D |
Data register |
| All |
ER |
PLC error status |
| All |
RT/WT |
Clock-Calendar |
| All |
RW |
Aux. Relay register |
| All |
S2 |
System info 2 |
| All |
SR |
System info 1 |
| All |
ST |
PLC status |
| All |
SW |
Special Register |
| All |
T |
Timer register |
| All |
XW |
External input register |
| All |
YW |
External output register |
| All (Except T1 Series) |
F |
F register |
| All (Except T1 Series) |
LW |
LW register |
| All (Except T1 Series) |
W |
W register |
Commands
| Device |
Command |
Description |
Uses |
| All |
DR |
Read data from registers |
- |
| All |
DW |
Write data to registers |
- |
| ALL |
ER |
PLC Error Status |
- |
| All |
RT |
Read PLC's built in Clock-Calendar data |
- |
| All |
S2 |
Read the PLC's system information 2 |
- |
| All |
SR |
Read the PLC's system information 1 |
- |
| All |
ST |
Read PLC operation status |
- |
| All |
WT |
Write to PLC's built in Clock-Calendar data |
- |
Signal
Conditionings
| Signal Type |
Description |
Comment |
Typical Gain |
Convergance Range |
| 12AL |
12 Bit Binary Scaled to EGUs - Alarming on out of range |
Ignores most significant 4 bits (nibble). |
- |
- |
| 12BN |
12 Bit Binary Scaled to EGUs- No Alarming on out of range |
Ignores most significant 4 bits (nibble). |
- |
- |
| 15AL |
15 Bit Binary Scaled to EGUs - Alarming on out of range |
Ignores most significant bit. |
- |
- |
| 15BN |
15 Bit Binary Scaled to EGUs - No Alarming on out of range |
Ignores most significant bit. |
- |
- |
| 3BCD |
3 Digit Binary Coded Decimal |
Scaled to EGUs. Alarming on out of range.
Ignores most significant 4 bits (nibble). |
- |
- |
| 4BCD |
4 Digit Binary Coded Decimal |
Scaled to EGUs. Alarming on out of range. |
- |
- |
| LIN |
Value scaled to EGUs |
No alarming on out of range. Signed and Unsigned data types. |
- |
- |
| NONE |
Returns raw value |
No alarming on out of range. |
- |
- |
History
| Revision History |
Reason for 6.01 Release on 9/21/98:
* Corrected communication to EX100 device and bit write problem.
Reason for 6.01a Release on 7/12/00:
* Corrected a problem with digital writes not working when connected to T-Series devices. EX100 devices appear to
function correctly.
Reason for 6.01b Release on 03/27/2003:
* Modified documentation to comply with GE standards.
Reason for 6.01c Release on 08/17/2005:
* Updated to reflect GE Fanuc branding. |
|
|